Main type of DSP Air Cooled Induction Heating Machines:
Type | Output Power | Input Current | Output Frequency | Input Voltage |
---|---|---|---|---|
UM-DSP20AB-HF/UM-DSP20A-HF | 20KVA | 43A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP30AB-HF/UM-DSP30A-HF | 30KVA | 51A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP40AB-HF/UM-DSP40A-HF | 40KVA | 68A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP60AB-HF/UM-DSP60A-HF | 60KVA | 101A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP80AB-HF/UM-DSP80A-HF | 80KVA | 135A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP100AB-HF/UM-DSP100A-HF | 100KVA | 164A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP120AB-HF/UM-DSP120A-HF | 120KVA | 203A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP160AB-HF/UM-DSP160A-HF | 160KVA | 270A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP240AB-HF/UM-DSP240A-HF | 240KVA | 406A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP320AB-HF/UM-DSP320A-HF | 320KVA | 540A | 30KHz~100KHz | 380VAC/3 Phase |
UM-DSP20AB-MF/UM-DSP20A-MF | 20KVA | 43A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP30AB-MF/UM-DSP30A-MF | 30KVA | 51A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP40AB-MF/UM-DSP40A-MF | 40KVA | 68A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP60AB-MF/UM-DSP60A-MF | 60KVA | 101A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP80AB-MF/UM-DSP80A-MF | 80KVA | 135A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP100AB-MF/UM-DSP100A-MF | 100KVA | 164A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP120AB-MF/UM-DSP120A-MF | 120KVA | 203A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP160AB-MF/UM-DSP160A-MF | 160KVA | 270A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP240AB-MF/UM-DSP240A-MF | 240KVA | 406A | 1KHz~20KHz | 380VAC/3 Phase |
UM-DSP320AB-MF/UM-DSP320A-MF | 320KVA | 540A | 1KHz~20KHz | 380VAC/3 Phase |
Main Parameters of DSP Air Cooled Induction Heating Machines:
Item | Description | Remark |
---|---|---|
Output Power | 20KW ~ 320KW | |
Output Frequency | 1KHz~20KHz | Medium Frequency |
30KHz~100KHz | High Frequency | |
Output Power Scope | 1~100% | |
Closed-Loop Control Stability | 0.5% | |
Efficiency | ≥95% | including isolation transformer |
Power Factor | ≥0.90 | |
Over Load Ability | 1.1 times of 1 minute | |
IP level | IP20 | |
Cooling Type | air cooled for main machine and transformer | water cooled or air cooled for induction coil |
Environment Temperature | -20℃~40℃ | 0-100% load |
40℃~55℃ | output power derated | |
Environment Humidity | ≤95% | non condensing |
Altitude | ≤1500 meter | output power derated when higher than 1500m |
UM-DSP100AB-HF induction heater
U shape air cooled induction coil by UM-100C-HF
U shape air cooled induction coil with UM-DSP100AB-HF
Newest Comment